Welcome to the new Xylem Flow Control Website
You have perhaps been redirected here from one of our Brand websites, this new site brings together all our brands
under one combined site with the same features and content you had before and some new.
  Close this message
X
Xylem Flow Control
Xylem Flow Control

Xylem Flow Control

  • Home
  • About Xylem
  • Literature
  • News & Events
  • Support Center
  • Contact Us
    • Send Enquiry
    • Factory Locations

Special Industrial / Carwash / Motor Operated Diaphragm Pumps
Duplex II AC Demand Pump Duplex II AC Demand Pump
Duplex II AC Demand Pump
 Click image to enlarge


     
    DISTRIBUTOR LOCATOR:


    Duplex II AC Demand Pump


    Self-priming diaphragm pump with 110-240v AC electric motors. Flow rates from 4-8 litres/min (1-2.1 US gallons/min), pressure switch control or with a bypass, or both, capable of pressures up to 6.5bar (95psi)


    Model No.: Duplex II AC Demand
    • Handles Water-like and Views Liquids Up to 250 cP
    • Chemical-resistant polypropylene pump head for long life
    • Latest techhnology internal check-valves for reliable self-priming
    • Choice of elastomers for maximum chemical compatibility
    • Internal bypass for excellent performance range
    • Optional pressure-switch control to run the pump only as needed
    • Available with long running heavy duty motor with built-in thermal overload
    • Available with commercial-duty DC monitor for continuous operation


     
     
    • Specifications
    • 21 Models
    • Downloads
    Voltage 115 & 230 (VAC)
    Flow Rate Up to 2.2 US Gallons/Min (8.6 Litres/Min)
    Max. Pressure up to 100psi (6.9bar)
    Elastomers EPDM, Santoprene, Nitrile or Viton
    Port Type 3/8"
    D3635E7011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    D7635I7011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers Nitrile Diaphragm and Valves

    D1635J7011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    D1625E6011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    Dx625I6011 Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers Nitrile Diaphragm and Valves

    D1625J6011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    D1631H5011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and EPDM Valves

    Dx631I5011 Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Nitrile Diaphragm and EPDM Valves

    D1631F5011A Duplex II AC Demand Pump
    Voltage 115 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and Viton Valves

    DX735E7011 Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    D1735J7011A Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    DX725E6011 Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    DX725J6011 Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    Dx731H5011 Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and EPDM Valves

    Dx731F5011 Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and Viton Valves

    D1735E7011ARL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    D1735J7011ARL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 2.2 US Gallons/Min (8.6 Litres/Min)
    Amp Draw 1.0 (amp)
    Max. Pressure 100psi (6.9bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    D1725E6011ARL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Valves

    D1725J6011ARL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.9 (amp)
    Max. Pressure 80psi (5.4bar) Switch with External Bypass
    Elastomers EPDM Diaphragm and Viton Valves

    Dx731H5011xRL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and EPDM Valves

    Dx731F5011xRL Duplex II AC Demand Pump
    Voltage 230 (VAC)
    Flow Rate 1.6 US Gallons/Min (6 Litres/Min)
    Amp Draw 0.8 (amp)
    Max. Pressure 60psi (4.1bar) Switch with External Bypass
    Elastomers Santoprene Diaphragm and Viton Valves

     Technical Data Sheet
     Duplex II (LP) Series Installation and Service Data
     Duplex II (HP) Series Installation and Service Data

     
    • Home
    • About Xylem
    • Literature
    • News & Events
    • Support Center
    • Legal Disclaimer
    • Privacy Policy
    • Accessibility
    • Site Map

    Channel Partners Sign-In