Welcome to the new Xylem Flow Control Website
You have perhaps been redirected here from one of our Brand websites, this new site brings together all our brands
under one combined site with the same features and content you had before and some new.
  Close this message
X
Xylem Flow Control
Xylem Flow Control

Xylem Flow Control

  • Home
  • About Xylem
  • Literature
  • News & Events
  • Support Center
  • Contact Us
    • Send Enquiry
    • Factory Locations

Oil & Gas / Valve Actuation / Direct Acting Valves
1500 Series Direct Acting Spool Valve 1500 Series Direct Acting Spool Valve 1500 Series Direct Acting Spool Valve
1500 Series Direct Acting Spool Valve
 Click image to enlarge


     
    DISTRIBUTOR LOCATOR:


    1500 Series Direct Acting Spool Valve


    Direct acting solenoid operated valves in stainless steel for use on gases and liquids


    • Solenoid options
    • ATEX, UL, CSA approvals available


     
     
    • Specifications
    • Downloads
    Gases Filtered lubricated or non-lubricated air, inert gas, sweet (natural) gses. sour gas option available. (details on application)
    Liquids Low pressure hydraulic, mineral oil or water.
    Port(s) 1/4", 3/8", 1/2”NPT (BSP option available)
    Orifice 0.35 (inches)
    8.8 (mm)
    Cv (Kv) 0.86 (12.25)
    Working Pressure (gases and liquids); Maximum body pressure 20 bar (290 psi); Maximum operating pressure differential 10 bar (145 psi)
    Working Temperature Ambient temperature; -50ºC to +40ºC (-58ºF to +104ºF)
    Construction Materials Stainless Steel AISI 316 S11 to NACE MR-01-75 Body; 316 Stainless Steel Spindle; 316 Stainless Steel Springs; Nitrile (Buna N) Seals options: Fluoroelastomer and EPDM
    Solenoid Specifications Flameproof EExd IIC T6 to ATEX standard
    Degree of Protection IP67
    Body Materials 316 Stainless Steel
    Cable Entry M20 x 1.5
    Coil Voltages DC - 12v, 24v, 110v; AC - (50/60 Hz) 24v, 110v, 120v, 220v
    Voltage Tolerance +10% to -15%
    Power Consumption DC - 6 Watts; AC units fitted with DC rectifier
    Coil Insulation Class H
    Duty Cycle 100% Continuously Rated
    Earth Connections Internal and Extrenal
     Mid-acs 1500 series direct acting valve

     
    • Home
    • About Xylem
    • Literature
    • News & Events
    • Support Center
    • Legal Disclaimer
    • Privacy Policy
    • Accessibility
    • Site Map

    Channel Partners Sign-In